7296

T/Mon SLIM: Local/regional monitoring that you control

T/Mon SLIM Remote Alarm Monitoring System
T/Mon SLIM: Real-time visibility and powerful alarm processing, scaled to local/regional networks.
T/Mon Slim

The T/Mon SLIM Remote Alarm Monitoring System puts control over your alarms directly into your hands. T/Mon SLIM is a new model of the T/Mon Remote Alarm Monitoring System, scaled to the needs of small, local and regional networks.

Cost-effective and easy to install, T/Mon SLIM puts high-quality network alarm monitoring within the reach of any company and any maintenance department.

You can use T/Mon SLIM to:

View Interface Screen shots
The T/MonXM interface
makes alarm information
easy to find and understand.
View interface screen shots.

T/Mon SLIM gives you the advanced alarm monitoring capabilities of a full-scale T/Mon, at a scale suitable for managing your local or regional network.

Auto Control Slim
Automatically Control Remote Site Equipment:

The T/Mon SLIM's derived control formulas automatically issue control commands in response to alarm inputs. This requires no human intervention. You're still notified. The event is logged. Your reaction time is simply removed to speed the corrective action. The T/Mon SLIM fully supports control relays, including relays connected to legacy RTUs.

T/Mon Slim Back Panel
The T/Mon SLIM fits into any 19" or 23" rack, in any telco environment, without taking space from revenue generating equipment.
Full Specifications
Standard Input Protocols: DCP, DCPf, DCPx, Ping
Standard Output Protocols: DCP, DCPf, DCPx
Optional Input Protocols: ASCII, Badger, Cordell, DCM, E2A, Granger, Larse, Modbus, NEC, NTP, Pulsecom, SNMP, TABS, TBOS, Teltrac, TL1
Optional Output Protocols : ASCII, SNMP, TABS, TL1
Monitoring Capacity : 64 devices/10,000 alarm points
T/Mon GFX Users 2
Maximum Non-T/MonGFX users: 5
Dimensions: 5.25" H (3RU) x 17" W x 14" D
(13.34 cm x 43.18 cm x 35.56 cm)
Weight 10 lbs (4.54 Kg)
Mounting: 19" or 23" rack
Power Input: Dual -48 VDC
Dual -24 VDC (optional)
Current Draw 500 mA
Fuse: Two 2 Amp GMT
Serial Ports: 4 RJ45 Connectors
Serial Port Interface: RS-232 / 33.6 Modems vary on configuration
LAN Interface: 10/100 BaseT
Processor: 400 MHz
Windows: 90
Visual Display: Front panel LCD
Unit Controls: 4 LCD menu control buttons
Hardware Warranty: 2 years
Operating Temperature: 41-90 degrees F (5 to 35 degrees C)
Operating Humidity: 0%-95% noncondensing
Optional Accessory: T/MON Site Dialer (plus T/MON EXP)

T/Mon Slim can be used to Mediate SCADA protocols to SNMP
View SCADA knowledge base

Graph and Analyze Diagram
Graph and Analyze Alarm History:

The T/Mon SLIM records up to 999,999 system events. These can be viewed in a variety of report formats. Alarm information can also be exported as ASCII text. That text can be sent to an after-hours recording device. It can also be imported into a database or spreadsheet program for graphing and analysis.

T/Mon Slim
Monitor Alarms from your NOC, Web Browser, E-Mail, or Pager:

The T/Mon SLIM gives you multiple options for accessing alarm data. This includes automatic e-mail and phone alerts. Automatic escalation alerts inform supervisors if technicians don't acknowledge alarms. Nuisance alarm filtering silences unimportant alarms. Text messages give precise instructions for resolving alarms.

T/Mon Voice Dialer Accessory

T/Mon Voice Dialer Accessory
The front and back panel of the T/Mon Voice Dialer accessory for T/Mon SLIM .

When combined with the T/Mon T/Mon SLIM master stations, the T/Mon Voice Dialer delivers another critical method of receiving alarm notifications. This application allows you to receive voice alerts for the alarm points databased in T/Mon.

Redundant Slims
Redundant Backup Monitoring:

You can use two or more T/Mon SLIM units in a network. One unit can be assigned to be a secondary backup. If the primary system goes down, the system will automatically switch all monitoring activity to the secondary system. This was traditionally done via a protection switch. A more modern architecture in newer T/Mon versions is to have your remotes report to both masters. The masters sync with each other. This keeps the secondary ready to take over at any time.

See Real-World T/Mon SLIM Applications and client reviews:


Get a Custom Application Diagram of Your Perfect-Fit Monitoring System

There is no other network on the planet that is exactly like yours. For that reason, you need to build a monitoring system that's the right fit for you.

"Buying more than you need" and "buying less than you need" are real risks. You also have to think about training, tech support, and upgrade availability.

Send me a quick online message about what you're trying to accomplish. I'll work with you to build a custom PDF application diagram that's a perfect fit for your network.


Make an Informed Decision


Your network isn't off-the-shelf.

Your monitoring system shouldn't be, either.

Customized monitoring application drawing

We'll walk you through this with a customized monitoring diagram.

Just tell us what you're trying to accomplish with remote monitoring.

Get a Custom Diagram